Housing easily removable for cleaning without tools. Pleasantly quiet. Dirt-free and quick replacement of existing EN units, as 100 % compatible with the predecessor EN and ET units. For existing electrical outside dampers with plug connection: Disconnect the plug and reconnect the individual wires according to the EN/ENR wiring diagrams on the Internet. Fan maintenance-free. Motor: Thermal overload protection as standard. Robust motor. Suitable for continuous operation. Electrical connection: Electrical connection either surface-mounted or flush-mounted. Safety instructions: The fan may only be put into operation if protection against contact with the impeller is ensured in accordance with DIN EN ISO 13857.Article: EN 20, delivery volume: 420 m3/h, speed: 1350 1/min, impeller type: axial, air direction: venting, speed controllable: yes, reversibility: no, voltage type: alternating current, rated voltage: 230 V, mains frequency: 50 Hz, rated power: 30 W, IMax: 0.21 A, protection class: IP 44, mains lead: 3 / 1.5 mm2, installation location: wall / ceiling, installation type: surface-mounted, installation position: any, material: plastic, colour: traffic white, similar to RAL 9016, weight: 2.475 kg, weight with packaging: 3.035 kg, nominal width: 200 mm, width: 320 mm, height: 320 mm, depth: 158 mm, width with packaging: 350 mm, height with packaging: 350 mm, depth with packaging: 170 mm, fluid temperature at IMax: 40 °C, sound pressure level: 45 dB(A)
PDF