Type: Sensus WMZ PolluCom F Qp 1.5 split device BL 110mm, G3/4" for R1/2" PEFB002A 7738336570 NEW
Compact heat meter PolluCom F screw-type meter, nominal flow rate qp 0.6 - 2.5, nominal width DN 15 - 20, nominal pressure PN 16, battery unit calculator with long-life battery and convenient LC display. Temperature measuring range 5 - 110C, temperature difference range 3 - 100 K. Optical data interface, M-Bus parameterisation function directly on the calculator. Storage of 18 monthly values for heat consumption and maximum values. Approved for all installation positions (except overhead). Flow sensor 5 - 90C, for split version cable length 0.3 m, calculator adjusted for installation in the colder line of the system, flow temperature sensor PT500, 45 mm,D: 5.2 mm, cable length 1.5 m, return temperature sensor integrated in the flow sensor. Possible communication options at extra charge: Wireless M-Bus according to OMS standard, Volume 2, Edition 4.0.2, M-Bus, remote metering pulse(1 kWh/pulse), factory-fitted, cannot be retrofitted. Optional: various temperature sensor cable lengths and designs
The meter may be installed in all mounting positions except overhead. Care must be taken to ensure the correct orientation of the calculator. The correct orientation can be found in the operating instructions.
Flow sensor:
Length L: 110 mm
Connection male: G3/4"
Nominal flow qp: 1.5 m3/h
Min. flow qi: 0.015 m3/h
Max. flow qs: 3.0 m3/h Max. flow qs: 3.0 m3/h Min. flow qi: 0.015 m3/h Max. flow qs: 0.015 m3/h Flow rate qs: 3.0 m3/h
Start-up value: 0.0025 m3/h
Pressure loss at qp: 0.17 bar
kvs value: 3.65 m3/h
Flow rate at 0.1 bar Pressure loss: 1.2 m3/h
Temperature range: 5 - 90C
Calculator:
Fast measuring cycle:
4 seconds for temperatures, power and flow rate
Temperature measuring range: 5 to 110C
Temperature difference: 3 to 100 K
Cut-off limit: 0.15 K
Measuring accuracy: better than +/- (0.5+dTmin/dT)%
Temperature sensor:
PT500, L:45mm, d=5,2mm, cable L:1,5m
Calibration fee/conformity fee Heat/cooling meter complete up to qp 6 m3/h
Order number: PEFB002A Compact heat meter, battery version
Consisting of:
flow sensor, calculator, direct-measuring platinum thermometer, sealing material, mounting set for sensor installation.
Approval according to the European Measuring Instruments Directive (MID) for any installation (except overhead)
Flow sensor:
Single-jet impeller meter, non-reactive electronic scanning directly at the impeller with 30 ml resolution.
Calculator:
Programmable, optical interface, 18 monthly values for heat consumption, volume, maximum values for flow rate and heat output, parameterisation function
directly on the calculator.